Viessmann Error Code 9E: Solarmodule delta-T monitoring failure, solar control (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code 9E on a boiler means: Solarmodule delta-T monitoring failure, solar control. It is also called Viessmann diagnostic code 9E.

Medium severityBoilerVersatronik 300

Homeowner? What Viessmann code 9E means for you

Check, then call Your boiler is reporting: Solarmodule delta-T monitoring failure, solar control. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code 9E mean?

Delta-T monitoring failure in the solar module.

Applies to: Versatronik 300 cascade control

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Boiler codes

CodeMeaning
8_190.Flue gas temperature
9Standby mode with frost protection monitoring
9 60Return temperature, 2nd sensor 17B (°C)
9ASolar collector temperature sensor open circuit
9BSolar collector return temperature sensor open circuit
9CSolar DHW tank temperature sensor open circuit
9FSolar general fault
9__50.Return temperature at sensor aJB (2nd return sensor)
10Short circuit, outdoor temperature sensor
11Safety shutdown
12 uService message: time interval reached
18Interruption, outdoor temperature sensor

All Viessmann Boiler error codes →

Viessmann code 9E: homeowner questions

What does Viessmann code 9E mean?

Solarmodule delta-T monitoring failure, solar control. Delta-T monitoring failure in the solar module.

Is it safe to keep using my boiler with code 9E?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Viessmann code 9E myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code 9E comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code 9E near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Versatronik 300 Cascade Control manual, p. 40. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.