Viessmann Error Code aCc: Return temperature sensor configuration error (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code aCc on a boiler means: Return temperature sensor configuration error. It is also called Viessmann diagnostic code aCc.

Medium severityBoilerVitotronic 100

Homeowner? What Viessmann code aCc means for you

Check, then call Your boiler is reporting: Return temperature sensor configuration error. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code aCc mean?

Controlled operation.

Applies to: Vitotronic 100 GC1 boiler control

Common causes of Viessmann code aCc

  • Coding 0C is set to 1 but plug aJA is not inserted.
  • Coding 4E is not set to 0.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code aCc

GC1KW10B

Other Viessmann Boiler codes

CodeMeaning
A7Wireless clock module fault
a9Communication fault with OpenTherm device
a 245Service message: maximum flue gas temperature reached (°C)
AAConfiguration failure TSA function
ABConfiguration failure heat exchanger setting
ACConfiguration failure return temperature control
aCdButterfly valve configuration error
ADConfiguration failure isolation valve control
AEInternal fault mixing valve
AFInternal fault mixing valve
a_245Maintenance: max flue gas temperature reached
B24 hour normal heating operation

All Viessmann Boiler error codes →

Viessmann code aCc: homeowner questions

What does Viessmann code aCc mean?

Return temperature sensor configuration error. Controlled operation.

Is it safe to keep using my boiler with code aCc?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Viessmann code aCc myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code aCc comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code aCc near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Viessmann Vitotronic 100 GC1 installation and service instructions, p. 102. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.