Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code 63572 h: Burner hours run, 1st stage (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code 63572 h on a boiler means: Burner hours run, 1st stage. It is also called Viessmann diagnostic code 63572 h.

Low severityBoilerVitotronic 100

Homeowner? What Viessmann code 63572 h means for you

Usually minor Your boiler is reporting: Burner hours run, 1st stage. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code 63572 h mean?

Approximate hours run for stage 1. Can be reset to 0 with the reset button.

Applies to: Vitotronic 100 GC1 operating status scan

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code 63572 h

GC1KW10B

Other Viessmann Boiler codes

CodeMeaning
03572.hBurner hours run, 1st stage
09572 hBurner hours run, 2nd stage
30417Burner starts
30417.Burner starts
35510Maintenance: burner run hours reached
35510 hService message: burner hours reached
AAUX demand active indicator
A.12Real-time clock battery flat
A.18Possible condensate back-up in heat cell
A.19Temperature limiter has responded
A.20Service interval could not be activated
A.48Reduced system output: condensate backup or wind influence

All Viessmann Boiler error codes →

Viessmann code 63572 h: homeowner questions

What does Viessmann code 63572 h mean?

Burner hours run, 1st stage. Approximate hours run for stage 1. Can be reset to 0 with the reset button.

Is it safe to keep using my boiler with code 63572 h?

Usually yes. Code 63572 h is normally minor, but if it keeps coming back have it checked.

Can I reset Viessmann code 63572 h myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code 63572 h comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code 63572 h near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Viessmann Vitotronic 100 GC1 installation and service instructions, p. 97. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977