Viessmann Error Code 81: Boiler water sensor drift (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code 81 on a boiler means: Boiler water sensor drift. It is also called Viessmann diagnostic code 81.

Medium severityBoilerVitotronic 300, GW6B

Homeowner? What Viessmann code 81 means for you

Check, then call Your boiler is reporting: Boiler water sensor drift. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code 81 mean?

Burner control unit is in a fault state.

Applies to: Boiler water temperature sensor

Common causes of Viessmann code 81

  • Sensor drift at boiler water temperature sensor
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Boiler codes

CodeMeaning
59Interruption, DHW tank temperature sensor 2
60Short circuit, return temperature sensor 17
68Interruption, return temperature sensor 17
70Short circuit, supply/return temperature sensor 17B
78Interruption, supply/return temperature sensor 17B
80Boiler water sensor short circuit
82Short circuit, burner control flue gas temperature limit sensor
83Sensor differential (drift), burner control flue gas temperature limit sensor
84Error boiler 1
85Error boiler 2
86Error boiler 3
87Error boiler 4

All Viessmann Boiler error codes →

Viessmann code 81: homeowner questions

What does Viessmann code 81 mean?

Boiler water sensor drift. Burner control unit is in a fault state.

Is it safe to keep using my boiler with code 81?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Viessmann code 81 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code 81 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code 81 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Vitotronic 300, GW6B installation and service instructions, p. 71. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.