Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code 33: Power supply voltage too low, internal fuse failure (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code 33 on a boiler means: Power supply voltage too low, internal fuse failure. It is also called Viessmann diagnostic code 33.

High severityBoilerVitodens 222-F

Homeowner? What Viessmann code 33 means for you

Call a technician Your boiler is reporting: Power supply voltage too low, internal fuse failure. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code 33 mean?

Detailed code 33 at coding address 38:XX. Power supply voltage is below the minimum operating level, or the internal fuse has failed.

Applies to: Vitodens 222-F B2TB

Common causes of Viessmann code 33

  • Power supply voltage below minimal operation level
  • Internal fuse failure
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code 33

222-F B2TB 19222-F B2TB 35222-F B2TB 68222-F B2TB 125B2TB 19B2TB 35B2TB 68B2TB 125VD2T 1HC1T4ZP.01VD2T 1HC1T4ZV.01Vitodens 222-F, B2TB 19Vitodens 222-F, B2TB 35Vitodens 222-F, B2TB 68Vitodens 222-F, B2TB 125

Other Viessmann Boiler codes

CodeMeaning
19Communication external outdoor temperature sensor
20Short circuit, supply temperature sensor HC1/system
28Interruption, supply temperature sensor HC1/system
29Open circuit at terminals 1 and L of power pump module
30Short circuit, boiler water temperature sensor
30 140Boiler water temperature sensor short circuit
38Interruption, boiler water temperature sensor
38 140Boiler water temperature sensor cable broken
40Short circuit, supply temperature sensor heating circuit 2
41Short circuit, return temperature sensor heating circuit 2
44Short circuit, supply temperature sensor heating circuit 3
45Short circuit, return temperature sensor heating circuit 3

All Viessmann Boiler error codes →

Viessmann code 33: homeowner questions

What does Viessmann code 33 mean?

Power supply voltage too low, internal fuse failure. Detailed code 33 at coding address 38:XX. Power supply voltage is below the minimum operating level, or the internal fuse has failed.

Is it safe to keep using my boiler with code 33?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code 33 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code 33 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code 33 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Vitodens 222-F B2TB service instructions, p. 80. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977