Viessmann error code 5o 45 on a boiler means: DHW tank temperature, 2nd sensor (°C). It is also called Viessmann diagnostic code 5o 45.

Low severityBoilerVitotronic 100

Homeowner? What Viessmann code 5o 45 means for you

Usually minor Your boiler is reporting: DHW tank temperature, 2nd sensor (°C). This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code 5o 45 mean?

Shown only when the second DHW tank temperature sensor is connected.

Applies to: Vitotronic 100 GC1 operating status scan

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code 5o 45

GC1KW10B

Other Viessmann Boiler codes

CodeMeaning
5 50DHW tank temperature, 1st sensor (°C)
5AOpen circuit, buffer tank
5CFailure boiler 5
5DFailure boiler 6
5EFailure boiler 7
5FFailure boiler 8
6Flame stabilizing
6 55Return temperature, 1st sensor 17A (°C)
6__45.Return temperature at sensor aJA (1st return sensor)
7Start-up partial load
7 70Return temperature sensor short circuit (outdoor reset without return sensor)
7 78Return temperature sensor cable break (outdoor reset without return sensor)

All Viessmann Boiler error codes →

Viessmann code 5o 45: homeowner questions

What does Viessmann code 5o 45 mean?

DHW tank temperature, 2nd sensor (°C). Shown only when the second DHW tank temperature sensor is connected.

Is it safe to keep using my boiler with code 5o 45?

Usually yes. Code 5o 45 is normally minor, but if it keeps coming back have it checked.

Can I reset Viessmann code 5o 45 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code 5o 45 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code 5o 45 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Viessmann Vitotronic 100 GC1 installation and service instructions, p. 97. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977