Updated · by Aurora Star Tech Inc.

Viessmann error code E6 on a boiler means: Flue gas/air supply system blocked. It is also called Viessmann diagnostic code E6.

High severityBoilerVersatronik 585

Homeowner? What Viessmann code E6 means for you

Call a technician Your boiler is reporting: Flue gas/air supply system blocked. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code E6 mean?

Flue or combustion air path is blocked. Gateway value 230 (dec).

Applies to: Viessmann Vitotronic controls via Versatronik 585 gateway

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code E6

Versatronik 585 VI/BACIP

Other Viessmann Boiler codes

CodeMeaning
E2 201Heating water flow rate too low during calibration
E3Safety chain error
E3 204Heat transfer too low at calibration
E4Fault, power supply voltage
E5Internal fault, combustion control unit
E5 226Flame amplifier fault
E7Ionization current too low during calibration
E7 192Ionization current too low at calibration
E8Ionization current outside permissible range
E8 189Ionization current outside permissible range
EAIonization current outside range during calibration
EA 193Ionization current deviation during calibration

All Viessmann Boiler error codes →

Viessmann code E6: homeowner questions

What does Viessmann code E6 mean?

Flue gas/air supply system blocked. Flue or combustion air path is blocked. Gateway value 230 (dec).

Is it safe to keep using my boiler with code E6?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code E6 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code E6 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code E6 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Versatronik 585 BACnetIP manual, p. 22. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.