Viessmann error code AE on a boiler means: Internal fault mixing valve. It is also called Viessmann diagnostic code AE.

High severityBoilerVersatronik 585

Homeowner? What Viessmann code AE means for you

Call a technician Your boiler is reporting: Internal fault mixing valve. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code AE mean?

Internal fault in the mixing valve. Gateway value 174 (dec).

Applies to: Viessmann Vitotronic controls via Versatronik 585 gateway

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code AE

Versatronik 585 VI/BACIP

Other Viessmann Boiler codes

CodeMeaning
AAConfiguration failure TSA function
ABConfiguration failure heat exchanger setting
ACConfiguration failure return temperature control
aCcReturn temperature sensor configuration error
aCdButterfly valve configuration error
ADConfiguration failure isolation valve control
AFInternal fault mixing valve
a_245Maintenance: max flue gas temperature reached
B24 hour normal heating operation
b0Short circuit, flue gas temperature sensor
B0 141Flue gas sensor shorted
b1Communication fault, programming unit (internal)

All Viessmann Boiler error codes →

Viessmann code AE: homeowner questions

What does Viessmann code AE mean?

Internal fault mixing valve. Internal fault in the mixing valve. Gateway value 174 (dec).

Is it safe to keep using my boiler with code AE?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code AE myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code AE comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code AE near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Versatronik 585 BACnetIP manual, p. 21. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977