Updated · by Aurora Star Tech Inc.

Viessmann error code A7 on a boiler means: Wireless clock module fault. It is also called Viessmann diagnostic code A7.

Low severityBoilerVersatronik 585

Homeowner? What Viessmann code A7 means for you

Usually minor Your boiler is reporting: Wireless clock module fault. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code A7 mean?

Fault in the control's wireless clock module. Gateway value 167 (dec).

Applies to: Viessmann Vitotronic controls via Versatronik 585 gateway

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code A7

Versatronik 585 VI/BACIP

Other Viessmann Boiler codes

CodeMeaning
A.48Reduced system output: condensate backup or wind influence
A0Fault/failure module 2, safety device input 1
A1Fault/failure module 2, safety device input 2
A2Fault/failure module 2, safety device input 3
A3Fault/failure module 2, safety device input 4
A4Fault/failure module 2, external
a9Communication fault with OpenTherm device
a 245Service message: maximum flue gas temperature reached (°C)
AAConfiguration failure TSA function
ABConfiguration failure heat exchanger setting
ACConfiguration failure return temperature control
aCcReturn temperature sensor configuration error

All Viessmann Boiler error codes →

Viessmann code A7: homeowner questions

What does Viessmann code A7 mean?

Wireless clock module fault. Fault in the control's wireless clock module. Gateway value 167 (dec).

Is it safe to keep using my boiler with code A7?

Usually yes. Code A7 is normally minor, but if it keeps coming back have it checked.

Can I reset Viessmann code A7 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code A7 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code A7 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Versatronik 585 BACnetIP manual, p. 21. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.