Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code 30: Short circuit, boiler water temperature sensor (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code 30 on a boiler means: Short circuit, boiler water temperature sensor. It is also called Viessmann diagnostic code 30.

Medium severityBoilerVersatronik 585

Homeowner? What Viessmann code 30 means for you

Check, then call Your boiler is reporting: Short circuit, boiler water temperature sensor. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code 30 mean?

Boiler water sensor is shorted. Gateway value 48 (dec).

Applies to: Viessmann Vitotronic controls via Versatronik 585 gateway

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code 30

Versatronik 585 VI/BACIP

Other Viessmann Boiler codes

CodeMeaning
12 uService message: time interval reached
18Interruption, outdoor temperature sensor
19Communication external outdoor temperature sensor
20Short circuit, supply temperature sensor HC1/system
28Interruption, supply temperature sensor HC1/system
29Open circuit at terminals 1 and L of power pump module
30 140Boiler water temperature sensor short circuit
33Power supply voltage too low, internal fuse failure
38Interruption, boiler water temperature sensor
38 140Boiler water temperature sensor cable broken
40Short circuit, supply temperature sensor heating circuit 2
41Short circuit, return temperature sensor heating circuit 2

All Viessmann Boiler error codes →

Viessmann code 30: homeowner questions

What does Viessmann code 30 mean?

Short circuit, boiler water temperature sensor. Boiler water sensor is shorted. Gateway value 48 (dec).

Is it safe to keep using my boiler with code 30?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Viessmann code 30 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code 30 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code 30 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Versatronik 585 BACnetIP manual, p. 21. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977