Weil-McLain Error Code Supply 60F > Return: Supply more than 60F above return (soft lockout) (Boiler)

Updated · by Aurora Star Tech Inc.

Weil-McLain error code Supply 60F > Return on a boiler means: Supply more than 60F above return (soft lockout). It is also called Weil-McLain diagnostic code Supply 60F > Return.

High severityBoilerECO Tec series 3

Homeowner? What Weil-McLain code Supply 60F > Return means for you

Call a technician Your boiler is reporting: Supply more than 60F above return (soft lockout). The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code Supply 60F > Return mean?

Shows when boiler outlet is more than 60F above boiler inlet, or when the burner has run less than 2 minutes. If it happens after 2 minutes of burner run, the burner stops with no message. Lockout times rise each time: 2 min 30 s, 3 min 30 s, 4 min 30 s, 5 min 30 s, then 6 min 30 s. After that the system retries every 6 min 30 s while temperatures stay under the limit. Two minutes of firing without exceeding 60F resets the timer to 2 min 30 s.

Applies to: ECO Tec series 3 80/110/150/199

Common causes of Weil-McLain code Supply 60F > Return

  • Insufficient water flow through the boiler
  • Circulators undersized or incorrectly installed
  • Circulator wiring fault
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Weil-McLain Boiler codes

CodeMeaning
RETURN > SUPPLYReturn temperature above supply
Software IncompatibleMain control and display software mismatch
SPILL SWITCHSpill switch open (flue gas spilling at the draft hood)
STANDBYStandby display
SUPPLY 58F > RETURNSupply temperature far above return
SUPPLY 58° F > RETURNSupply exceeds return by 58°F
SUPPLY WATER TEMPERATURE TOO HIGHSupply temperature above 200°F while burner runs
System Return > SupplySystem return hotter than system supply
Target Reduced - BoilerTarget reduced because boiler outlet is near max temperature
Target Reduced - FlowTarget reduced for low water flow across heat exchanger
Target Reduced - FlueTarget reduced for high flue temperature
TEMPERATURE SENSORTemperature sensor short, open, or readings disagree

All Weil-McLain Boiler error codes →

Weil-McLain code Supply 60F > Return: homeowner questions

What does Weil-McLain code Supply 60F > Return mean?

Supply more than 60F above return (soft lockout). Shows when boiler outlet is more than 60F above boiler inlet, or when the burner has run less than 2 minutes. If it happens after 2 minutes of burner run, the burner stops with no message. Lockout times rise each time: 2 min 30 s, 3 min…

Is it safe to keep using my boiler with code Supply 60F > Return?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Weil-McLain code Supply 60F > Return myself?

You can try one reset (power off for 30 seconds, then on). If Weil-McLain code Supply 60F > Return comes back, the cause is still there and a licensed technician should check it.

Who can fix Weil-McLain code Supply 60F > Return near me?

Aurora Star Tech Inc. repairs Weil-McLain boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: ECO Tec Series 3 boiler manual, p. 168. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.