Weil-McLain Boiler: Clean the steam gauge glass
Clean the steam gauge glass on a Weil-McLain boiler: Normal steam waterline is halfway up the gauge glass. Clean when needed with pressure low.
Applies to: Steam boilers
Common causes of clean the steam gauge glass
- Sediment or scale in the gauge glass
How to fix clean the steam gauge glass: step by step
- Make sure boiler pressure is low.
- Close the lower gauge cock.
- Open the pet cock.
- Open the lower gauge cock and flush a small amount of water through the pet cock.
- Close the lower gauge cock, then close the pet cock.
- Reopen the lower gauge cock.
- If the glass breaks, close both gauge cocks and call a technician. Do not fit thin glass tubing.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: Gas-Fired Boilers User Manual 550-100-226/0425, p. 21. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.