Weil-McLain Boiler: Servicing the domestic water outlet manifold (heating cartridge and sanitary shutter)

Updated · by Aurora Star Tech Inc.

Servicing the domestic water outlet manifold (heating cartridge and sanitary shutter) on a Weil-McLain boiler: Clean and inspect the cartridge and shutter, replace worn O-rings and reassemble with the torque values in the torque table.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: 80/110/150/199 Series 3

Common causes of servicing the domestic water outlet manifold (heating cartridge and sanitary shutter)

  • Worn or damaged valve shutter, springs or seats

How to fix servicing the domestic water outlet manifold (heating cartridge and sanitary shutter): step by step

  1. Follow the gas and electrical shut-off steps and the brazed plate steps 1 through 6 on page 156.
  2. Slide the actuator retaining clip out of its slot and remove the actuator, keeping its wire attached.
  3. Remove the spacer with a 28mm (1 1/8 in) wrench, which takes the sanitary shutter with it.
  4. Remove the heating cartridge with a 22mm (7/8 in) wrench.
  5. Clean the cartridge and shutter. Compress the springs to check them. Replace any damaged or heavily worn parts.
  6. Check both O-rings and seats. Replace O-rings if needed, clean the seats and lightly grease with non-petroleum grease.
  7. Grease the tip of the shutter rod and reassemble it with the spacer. Put it in the outlet manifold without tightening.
  8. Screw the heating cartridge in and torque to the value in the torque table.
  9. Tighten the spacer to the value in the torque table.
  10. Reinstall the actuator and retaining clip.
  11. The DHW temperature sensor is in this manifold. Verify it using the temperature sensor check.
  12. Open the CH supply and return valves, refill the boiler, purge air and check all joints for leaks.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: ECO Tec series 3 boiler manual, p. 158. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.