Weil-McLain Boiler: Four-zone space heating without DHW (Example A)

Updated · by Aurora Star Tech Inc.

Four-zone space heating without DHW (Example A) on a Weil-McLain boiler: If DHW is not used, the boiler can run a fourth space heating zone from Input/Output 1.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: ECO Tec Series 3, Express Setup Example A

How to fix four-zone space heating without dhw (example a): step by step

  1. Set Input/Output 1 exactly the same as Input/Output 2.
  2. Assign Input/Output 1 to PRIORITY 2.
  3. Wire the fourth zone thermostat to J17 terminals 1 and 2.
  4. Wire the fourth zone circulator to T2 terminals 4, 5 and 6.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

More other tips for boiler

Source: ECO Tec Series 3 boiler manual, p. 98. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.