Weil-McLain Boiler: Connect condensate trap line

Updated · by Aurora Star Tech Inc.

Connect condensate trap line on a Weil-McLain boiler: Hose clamps secure the trap line. The method changes between the smaller Ultra-80 and -105 and the Ultra-155 and larger.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: All Ultra models

How to fix connect condensate trap line: step by step

  1. Ultra-80 and -105: guide the trap line through the bracket hole.
  2. Ultra-80 and -105: clamp one end to the heat exchanger condensate connection, then clamp the other end over the reducing elbow.
  3. Ultra-155 and larger: slide a hose clamp over each end of the trap line.
  4. Ultra-155 and larger: slide the trap line onto the heat exchanger connection and the PVC reducing elbow, then tighten both clamps (Figure 30 or 31, page 28).
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: Weil-McLain Ultra Series 4 boiler manual, p. 27. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.