Weil-McLain Boiler: First-year special inspection

Updated · by Aurora Star Tech Inc.

First-year special inspection on a Weil-McLain boiler: Extra inspection due no later than 12 months after installation.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: ECO Tec Series 3 gas boilers

Common causes of first-year special inspection

  • Heavy fouling of heat exchanger or condensate lines
  • Combustion air contamination

How to fix first-year special inspection: step by step

  1. Obtain a Weil-McLain maintenance kit before starting.
  2. Inspect the heat exchanger and clean if needed (p. 150).
  3. Inspect the cover plate insulation and gasket; replace if not in good condition.
  4. Inspect the burner and clean it with a vacuum and compressed air if needed.
  5. Make sure there is no blockage or debris in the burner or burner ports; replace the burner if needed.
  6. Check burner tightness. Remove cover plate insulation and tighten burner screws if needed (p. 151).
  7. Check the vent seals with the mirror method (p. 136).
  8. Disconnect the condensate trap and drain lines, inspect and flush, then reinstall and refill the trap (p. 132).
  9. If the heat exchanger is heavily fouled or condensate lines show sediment, schedule a follow-up inspection sooner than 12 months.
  10. If heavy fouling suggests combustion air contamination, inspect the air intake area and remove contaminants (p. 25).
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: ECO Tec series 3 boiler manual, p. 139. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.