Weil-McLain Error Code TEMPERATURE SENSOR: Temperature sensor short, open, or readings disagree (Boiler)

Updated · by Aurora Star Tech Inc.

Weil-McLain error code TEMPERATURE SENSOR on a boiler means: Temperature sensor short, open, or readings disagree. It is also called Weil-McLain diagnostic code TEMPERATURE SENSOR.

Medium severityBoilerUltra Series 4

Homeowner? What Weil-McLain code TEMPERATURE SENSOR means for you

Check, then call Your boiler is reporting: Temperature sensor short, open, or readings disagree. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code TEMPERATURE SENSOR mean?

Covers two conditions with the same message: a sensor is shorted or disconnected (SHORT or OPEN), or dual sensor readings differ by more than 10 °F. Clears automatically when the condition ends. Optional outdoor and system sensors always show OPEN when not installed, which is normal.

Applies to: Ultra 80, 105, 155, 230, 299, 399

Common causes of Weil-McLain code TEMPERATURE SENSOR

  • Shorted or open sensor
  • Loose connection or poor pin engagement in the harness
  • Failed U-Control module

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Weil-McLain Boiler codes

CodeMeaning
Supply 60F > ReturnSupply more than 60F above return (soft lockout)
SUPPLY WATER TEMPERATURE TOO HIGHSupply temperature above 200°F while burner runs
System Return > SupplySystem return hotter than system supply
Target Reduced - BoilerTarget reduced because boiler outlet is near max temperature
Target Reduced - FlowTarget reduced for low water flow across heat exchanger
Target Reduced - FlueTarget reduced for high flue temperature
TEMPERATURE SENSOR FAULTTemperature sensor shorted or open
TEMP RISE TOO QUICKLYSupply water temperature rising too fast
Unconfigured Net 1 or Net 2 DemandNet 1 or Net 2 input active but not configured
Virtual Input ActiveModbus commanding a virtual TT input

All Weil-McLain Boiler error codes →

Weil-McLain code TEMPERATURE SENSOR: homeowner questions

What does Weil-McLain code TEMPERATURE SENSOR mean?

Temperature sensor short, open, or readings disagree. Covers two conditions with the same message: a sensor is shorted or disconnected (SHORT or OPEN), or dual sensor readings differ by more than 10 °F. Clears automatically when the condition ends. Optional outdoor and system sensors always…

Is it safe to keep using my boiler with code TEMPERATURE SENSOR?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Weil-McLain code TEMPERATURE SENSOR myself?

You can try one reset (power off for 30 seconds, then on). If Weil-McLain code TEMPERATURE SENSOR comes back, the cause is still there and a licensed technician should check it.

Who can fix Weil-McLain code TEMPERATURE SENSOR near me?

Aurora Star Tech Inc. repairs Weil-McLain boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Ultra Series 4 gas-fired water boiler manual, p. 120. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.