Weil-McLain Boiler: Model number suffix codes
Model number suffix codes on a Weil-McLain boiler: Suffixes on EG-30 to EG-75 model numbers show the ignition type, fuel, boiler type and tankless heater option.
Applies to: EG-30 to EG-75 and PEG package models
How to fix model number suffix codes: step by step
- Add PID or PI for electronic ignition. The PID/PI suffix is required with a damper in the US (EG-30 to EG-65) and optional in Canada.
- Add N for natural gas.
- Add W for a water boiler, or S for a steam boiler.
- Add T for a tankless heater, or P for a provisional tankless heater.
- For a package boiler, add the P prefix (for example PEG-30-S through PEG-65-S).
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: EG / PEG Series 7 Natural Gas-Fired Boiler Manual, p. 89. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.