Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Weil-McLain Error Code Target Reduced – Flow: Target reduced for low water flow across heat exchanger (Boiler)

Updated · by Aurora Star Tech Inc.

Weil-McLain error code Target Reduced - Flow on a boiler means: Target reduced for low water flow across heat exchanger. It is also called Weil-McLain diagnostic code Target Reduced - Flow.

Low severityBoilerECO Tec series 3

Homeowner? What Weil-McLain code Target Reduced - Flow means for you

Usually minor Your boiler is reporting: Target reduced for low water flow across heat exchanger. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code Target Reduced - Flow mean?

Boiler outlet sensor reads more than 50F above boiler inlet sensor. The control lowers the target to protect the heat exchanger. Clears when outlet is within 50F of inlet.

Applies to: ECO Tec series 3 80/110/150/199

Common causes of Weil-McLain code Target Reduced - Flow

  • Poor water flow through the boiler heat exchanger
  • Circulator malfunction or wiring problem
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Weil-McLain Boiler codes

CodeMeaning
SUPPLY 58F > RETURNSupply temperature far above return
SUPPLY 58° F > RETURNSupply exceeds return by 58°F
Supply 60F > ReturnSupply more than 60F above return (soft lockout)
SUPPLY WATER TEMPERATURE TOO HIGHSupply temperature above 200°F while burner runs
System Return > SupplySystem return hotter than system supply
Target Reduced - BoilerTarget reduced because boiler outlet is near max temperature
Target Reduced - FlueTarget reduced for high flue temperature
TEMPERATURE SENSORTemperature sensor short, open, or readings disagree
TEMPERATURE SENSOR FAULTTemperature sensor shorted or open
TEMP RISE TOO QUICKLYSupply water temperature rising too fast
Unconfigured Net 1 or Net 2 DemandNet 1 or Net 2 input active but not configured
Virtual Input ActiveModbus commanding a virtual TT input

All Weil-McLain Boiler error codes →

Weil-McLain code Target Reduced - Flow: homeowner questions

What does Weil-McLain code Target Reduced - Flow mean?

Target reduced for low water flow across heat exchanger. Boiler outlet sensor reads more than 50F above boiler inlet sensor. The control lowers the target to protect the heat exchanger. Clears when outlet is within 50F of inlet.

Is it safe to keep using my boiler with code Target Reduced - Flow?

Usually yes. Code Target Reduced - Flow is normally minor, but if it keeps coming back have it checked.

Can I reset Weil-McLain code Target Reduced - Flow myself?

You can try one reset (power off for 30 seconds, then on). If Weil-McLain code Target Reduced - Flow comes back, the cause is still there and a licensed technician should check it.

Who can fix Weil-McLain code Target Reduced - Flow near me?

Aurora Star Tech Inc. repairs Weil-McLain boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: ECO Tec Series 3 boiler manual, p. 168. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977