Weil-McLain Boiler: Check automatic air vent operation
Check automatic air vent operation on a Weil-McLain boiler: Test a system air vent before relying on it. The discharge water may be very hot.
Applies to: Automatic air vents
How to fix check automatic air vent operation: step by step
- Remove the cap from the air vent.
- Depress the valve briefly with a screwdriver tip to check it moves freely and does not leak.
- Replace cap A and turn it all the way on.
- Loosen cap A one turn so the vent can operate.
- Replace the vent if it does not work correctly.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: ECO Tec Series 3 boiler manual, p. 53. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.