Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Weil-McLain Boiler: Install the EG burner drawer assembly

Updated · by Aurora Star Tech Inc.

Install the EG burner drawer assembly on a Weil-McLain boiler: Drawer assembly holds the main burners, gas manifold and pilot burner. Burner seating and orifice sizing are critical.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: EG boilers; PEG arrives factory assembled

How to fix install the eg burner drawer assembly: step by step

  1. Fasten the front base panel (6 1/8 in. high) and rear base channel to the section assembly and seal the top with boiler cement.
  2. Check that the correct orifices are fitted (see orifice table, page 17).
  3. Place burners in the drawer as shown in Figures 10 and 11.
  4. Slide the drawer under the front base panel and attach to the section assembly as in Figure 9.
  5. Level and straighten the burners.
  6. Make sure burners sit in the slots of the back burner support with openings facing up, and that each gas orifice injects down the center of its burner.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: EG/PEG Series 7 boiler manual, p. 16. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair