Weil-McLain Boiler: Anti-scald valve required for Combi DHW

Updated · by Aurora Star Tech Inc.

Anti-scald valve required for Combi DHW on a Weil-McLain boiler: The DHW outlet of a Combi must have an anti-scald thermostatic mixing valve. Without one, DHW can cause scalding.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: ECO Tec 110 Combi and other Combi models

How to fix anti-scald valve required for combi dhw: step by step

  1. Confirm the anti-scald thermostatic mixing valve is installed, set and working before operating the boiler.
  2. If no mixing valve is installed, select DISABLE DHW to keep Combi features off while finishing setup.
  3. After the valve is installed, press ACCEPT. Combi features can be re-enabled later.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

More commissioning tips for boiler

Source: ECO Tec Series 3 boiler manual, p. 100. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.