Weil-McLain Boiler: Venting fittings and vent sizes
Venting fittings and vent sizes on a Weil-McLain boiler: ECO Tec boilers need Category IV venting. Use only the vent materials and methods in the manual. Vent and air pipe can be 2" or 3"; a 2" run needs an adapter. Air intake must be 3" PVC at the adapter; exhaust must be 3" PVC/PP/SS at the adapter. Use sweep elbows only, not short-radius elbows. Direct exhaust venting is possible with the kit option.
Applies to: ECO Tec 80/110/150/199 Series 3
How to fix venting fittings and vent sizes: step by step
- Confirm the vent is Category IV-rated material and method.
- Use an adapter if running 2" vent.
- Install 3" PVC air intake at the adapter and 3" PVC/PP/SS exhaust at the adapter.
- Use sweep elbows on all vent and air elbows.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
More commissioning tips for boiler
Source: ECO Tec Series 3 boiler manual, p. 184. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.