Weil-McLain Boiler: Sidewall concentric termination: location and clearances
Sidewall concentric termination: location and clearances on a Weil-McLain boiler: Pick a termination spot that keeps flue plume away from windows, plants, AC units and people, and out of wind eddies, inside corners and recessed areas. Terminate at least 6 ft from adjacent walls, at least 5 ft below a roof overhang, at least 7 ft above a public walkway, and at least 3 ft above any forced air intake within 10 ft. Keep the vent at least 12 in below or horizontally from any door, window or gravity inlet for appliances up to 150,000 BTU/hr, or 48 in for larger appliances. Keep the air inlet at least 12 in above grade or snow line. Keep the termination at least 4 ft horizontally from any electric meter, gas meter, regulator, relief valve or other equipment. Never terminate above or below these within 4 ft. Do not terminate above a door or window or under a deck.
Applies to: Sidewall 3 in or 4 in concentric vent/air termination
How to fix sidewall concentric termination: location and clearances: step by step
- Read the surroundings and avoid wind eddies, corners, window wells and recessed areas.
- Check each clearance against the minimums in this section before cutting any wall.
- Keep the termination out of reach of stones, balls, leaves and sediment, and guard it against condensate damage to finishes.
- Confirm a bird screen is fitted at every vent and air termination, buying it separately if the kit does not include one.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: Ultra Series 4 boiler manual, p. 72-73. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.