Weil-McLain Boiler: Operate the boiler relief valve (every 6 months)
Operate the boiler relief valve (every 6 months) on a Weil-McLain boiler: Manually lift the relief valve lever to confirm it passes water and reseats.
Applies to: All boilers in this manual
Common causes of operate the boiler relief valve (every 6 months)
- Valve or discharge line blocked
- Valve weeping after lifting
How to fix operate the boiler relief valve (every 6 months): step by step
- Confirm the discharge pipe runs to a safe drain point and cannot scald anyone.
- Read the boiler gauge to confirm the system is pressurized.
- Lift the relief valve lever slightly so water flows through the valve and discharge pipe.
- If water flows freely, release the lever and let the valve seat.
- Watch the discharge pipe to confirm the valve does not weep after it has drained.
- If the valve weeps, lift it again to try to clean the seat; if it still weeps, call a technician.
- If no water flows when the lever is fully lifted, shut the boiler down per the jacket instructions and call a technician.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: Gas-Fired Boilers User Manual 550-100-226/0425, p. 22. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.