Weil-McLain Boiler: Sidewall wall penetration and metal cover plates
Sidewall wall penetration and metal cover plates on a Weil-McLain boiler: The cover plates and thimble set the outer stop for the vent elbow. The plate hole sizes are not readable in the extracted text, so check them against the plate supplied with the boiler.
Applies to: Ultra direct exhaust sidewall termination
How to fix sidewall wall penetration and metal cover plates: step by step
- Cut a rough opening large enough to clear the metal thimble.
- Install a galvanized metal thimble (supplied by installer) in the vent pipe hole.
- Use cover plates with an outer plate that has a stop so the vent elbow cannot be pushed inward.
- Match the cover plate hole to the vent pipe size.
- For AL29-4C vent pipe, make the hole large enough to clear the pipe but too small for the elbow to pass through.
- Follow local codes for isolating vent pipe where it passes through floors or walls.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: Weil-McLain Ultra Series 4 boiler manual, p. 88. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.