Weil-McLain Error Code System Return > Supply: System return hotter than system supply (Boiler)

Updated · by Aurora Star Tech Inc.

Weil-McLain error code System Return > Supply on a boiler means: System return hotter than system supply. It is also called Weil-McLain diagnostic code System Return > Supply.

Medium severityBoilerECO Tec series 3

Homeowner? What Weil-McLain code System Return > Supply means for you

Check, then call Your boiler is reporting: System return hotter than system supply. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code System Return > Supply mean?

Occurs when system return is more than 10F above system supply, after the burner has run 10 minutes and the priority has not changed in the last 10 minutes. Clears automatically.

Applies to: ECO Tec series 3 80/110/150/199

Common causes of Weil-McLain code System Return > Supply

  • System sensors mounted on the boiler loop instead of system piping
  • Sensors wired to the wrong terminals
  • Sensors heated by proximity to the boiler loop connection
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Weil-McLain Boiler codes

CodeMeaning
SPILL SWITCHSpill switch open (flue gas spilling at the draft hood)
STANDBYStandby display
SUPPLY 58F > RETURNSupply temperature far above return
SUPPLY 58° F > RETURNSupply exceeds return by 58°F
Supply 60F > ReturnSupply more than 60F above return (soft lockout)
SUPPLY WATER TEMPERATURE TOO HIGHSupply temperature above 200°F while burner runs
Target Reduced - BoilerTarget reduced because boiler outlet is near max temperature
Target Reduced - FlowTarget reduced for low water flow across heat exchanger
Target Reduced - FlueTarget reduced for high flue temperature
TEMPERATURE SENSORTemperature sensor short, open, or readings disagree
TEMPERATURE SENSOR FAULTTemperature sensor shorted or open
TEMP RISE TOO QUICKLYSupply water temperature rising too fast

All Weil-McLain Boiler error codes →

Weil-McLain code System Return > Supply: homeowner questions

What does Weil-McLain code System Return > Supply mean?

System return hotter than system supply. Occurs when system return is more than 10F above system supply, after the burner has run 10 minutes and the priority has not changed in the last 10 minutes. Clears automatically.

Is it safe to keep using my boiler with code System Return > Supply?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Weil-McLain code System Return > Supply myself?

You can try one reset (power off for 30 seconds, then on). If Weil-McLain code System Return > Supply comes back, the cause is still there and a licensed technician should check it.

Who can fix Weil-McLain code System Return > Supply near me?

Aurora Star Tech Inc. repairs Weil-McLain boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: ECO Tec Series 3 boiler manual, p. 168. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.