Weil-McLain error code RETURN > SUPPLY on a boiler means: Return temperature above supply. It is also called Weil-McLain diagnostic code RETURN > SUPPLY.

Low severityBoilerUltra Series 4

Homeowner? What Weil-McLain code RETURN > SUPPLY means for you

Usually minor Your boiler is reporting: Return temperature above supply. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code RETURN > SUPPLY mean?

Return water temperature is 10 °F or more above the supply temperature. Applies to system sensors or boiler sensors. For system sensors the condition must last 10 minutes. Clears automatically when the condition ends.

Applies to: Ultra 80, 105, 155, 230, 299, 399

Common causes of Weil-McLain code RETURN > SUPPLY

  • Boiler circulator running in the wrong direction
  • System sensors placed on the boiler loop
  • System sensors heated by nearby boiler piping
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Weil-McLain Boiler codes

CodeMeaning
LWCO GREENLow water cutoff indicator green
LWCO REDLow water cutoff indicator red
MANUAL LIMITManual-reset limit circuit open (includes rollout switch)
NO DISPLAY - BOILER RUNNINGDisplay blank while boiler is operating
NO DISPLAY - NO 24VNo display, no 24V control power
NO DISPLAY - NO 120VNo display and no boiler components running, no 120V power
Software IncompatibleMain control and display software mismatch
SPILL SWITCHSpill switch open (flue gas spilling at the draft hood)
STANDBYStandby display
SUPPLY 58F > RETURNSupply temperature far above return
SUPPLY 58° F > RETURNSupply exceeds return by 58°F
Supply 60F > ReturnSupply more than 60F above return (soft lockout)

All Weil-McLain Boiler error codes →

Weil-McLain code RETURN > SUPPLY: homeowner questions

What does Weil-McLain code RETURN > SUPPLY mean?

Return temperature above supply. Return water temperature is 10 °F or more above the supply temperature. Applies to system sensors or boiler sensors. For system sensors the condition must last 10 minutes. Clears automatically when the condition ends.

Is it safe to keep using my boiler with code RETURN > SUPPLY?

Usually yes. Code RETURN > SUPPLY is normally minor, but if it keeps coming back have it checked.

Can I reset Weil-McLain code RETURN > SUPPLY myself?

You can try one reset (power off for 30 seconds, then on). If Weil-McLain code RETURN > SUPPLY comes back, the cause is still there and a licensed technician should check it.

Who can fix Weil-McLain code RETURN > SUPPLY near me?

Aurora Star Tech Inc. repairs Weil-McLain boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Ultra Series 4 gas-fired water boiler manual, p. 120. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.