Updated · by Aurora Star Tech Inc.

Weil-McLain error codes and diagnostic codes: look up a code to see what it means, the likely causes and the steps to fix it.

Weil-McLain error codes by equipment type

Weil-McLain Boiler error codes

CodeMeaning
AIR PRESSURE SW FAULTAir pressure switch input open
AUTO LIMITAuto-reset limit circuit open
BLOWER FAULTBlower speed fault
BOILER OUT OPENBoiler outlet sensor open circuit
BOILER OUT SHORTBoiler outlet sensor shorted
BURNER ONBurner on status
CHCentral heat call active
CH VOLTAGE HIGHToo much voltage on the CH / Thermostat 1 input
CONFIG MISMATCHStored configuration does not match the harness
CONFIGURATIONControl board not configured
DHWDomestic hot water call active
DHW VOLTAGE HIGHToo much voltage on the DHW / Thermostat 2 input
DISPLAY COMMDisplay communication lost
EXP BOARD COM FAULTExpansion board to U-Control communication fault
FALSE FLAMEFlame sensed when the gas valve is off
FAULT L1 POLARITYLine 1 polarity reversed
FAULT MANUAL LIMITManual limit fault
FLAME FAULTFlame detected when no flame should exist
FLAME LOSTFlame lost while running
FLUE TEMP TOO HIGHFlue gas temperature too high
GAS PRESSURE SW FAULTGas pressure switch open
GAS VALVE FAULTGas valve output circuit fault
GV FAULT EXPANSION BRDExpansion board gas valve output fault
HARDWARE FAULT 1Control board hardware fault 1
HARDWARE FAULT 2Control board hardware fault 2
HARDWARE FAULT 3Control board hardware fault 3
HARDWARE FAULT 4Control board hardware fault 4
HARDWARE FAULT 5Pilot valve output fault (board or harness short)
HARDWARE FAULT 6Control board hardware fault 6
HARDWARE FAULT 7Main valve output fault (board or harness short)
HARDWARE FAULT 8Control board hardware fault 8
HIGH TEMP LIMITHigh temperature limit reached
HW FAULT EXPANSION BRDExpansion control board hardware fault
IGNITION FAULTNo flame after 5 ignition attempts
L1 POLARITYLine voltage polarity reversed
LIMIT OPENExternal limit open
LOW WTR CUTOFF OPENLow water cutoff contacts open
LWCOLow water cutoff active / LWCO test
LWCO GREENLow water cutoff indicator green
LWCO REDLow water cutoff indicator red
MANUAL LIMITManual-reset limit circuit open (includes rollout switch)
NO DISPLAY - BOILER RUNNINGDisplay blank while boiler is operating
NO DISPLAY - NO 24VNo display, no 24V control power
NO DISPLAY - NO 120VNo display and no boiler components running, no 120V power
RETURN > SUPPLYReturn temperature above supply
Software IncompatibleMain control and display software mismatch
SPILL SWITCHSpill switch open (flue gas spilling at the draft hood)
STANDBYStandby display
SUPPLY 58F > RETURNSupply temperature far above return
SUPPLY 58° F > RETURNSupply exceeds return by 58°F
Supply 60F > ReturnSupply more than 60F above return (soft lockout)
SUPPLY WATER TEMPERATURE TOO HIGHSupply temperature above 200°F while burner runs
System Return > SupplySystem return hotter than system supply
Target Reduced - BoilerTarget reduced because boiler outlet is near max temperature
Target Reduced - FlowTarget reduced for low water flow across heat exchanger
Target Reduced - FlueTarget reduced for high flue temperature
TEMPERATURE SENSORTemperature sensor short, open, or readings disagree
TEMPERATURE SENSOR FAULTTemperature sensor shorted or open
TEMP RISE TOO QUICKLYSupply water temperature rising too fast
Unconfigured Net 1 or Net 2 DemandNet 1 or Net 2 input active but not configured
Virtual Input ActiveModbus commanding a virtual TT input

Weil-McLain Heat Pump error codes

CodeMeaning
bHPED board fault
C7Inverter heat sink too hot
CLWater pump communication wire fault
E0Water flow fault (E8 three times)
E2Communication fault between wired controller and indoor unit
E5Outdoor coil temperature sensor (T3) fault
E6Outdoor air temperature sensor (T4) fault
E7Buffer tank temperature sensor (Tbt1) fault
E8Water flow fault
E9Compressor suction temperature sensor (Th) fault
EACompressor discharge temperature sensor (Tp) fault
EbSolar panel temperature sensor (Tsolar) fault
EdWater inlet temperature sensor (Tw_in) fault
EEHydro-box PCB EEPROM fault
ELCommunication fault between hydraulic module and MH-kit
F1DC bus low voltage
H0Communication fault between indoor and outdoor unit
H1Communication fault between main board and inverter board (outdoor)
H2Refrigerant temperature sensor at plate HX outlet (heating) (T2) fault
H3Refrigerant temperature sensor at plate HX inlet (heating) (T2B) fault
H4L0/L1 protection happened 3 times in an hour
H5Room temperature sensor (Ta) fault
H6DC fan motor fault
H7AC supply voltage protection
H8Pressure sensor fault
H9Zone 2 water temperature sensor (Tw2) fault
HAWater outlet temperature sensor (Tw_out) fault
HbPP three times and Tw_out under 44.6 F
HECommunication fault with Ta / room thermostat transfer board
HFOutdoor unit EEPROM fault
HHH6 fan fault 10 times in 120 minutes
HPLow pressure in cooling, 3 times in an hour
L0DC compressor inverter module fault
L1DC bus low voltage protection
L2DC bus high voltage protection
L4MCE fault
L5Zero speed protection
L7Phase loss protection
L8Compressor speed changed more than 15 Hz in one second
L9Compressor speed off target by more than 15 Hz
P0Low pressure protection
P1High pressure protection
P3AC current protection
P4Compressor discharge temperature too high
P5Water temperature difference too high (Tw_out - Tw_in)
P6Inverter module protection
PbAnti-freeze mode
PdOutdoor coil (T3) temperature too high
PPTw_out - Tw_in reading not normal

Find codes by Weil-McLain model

ECO HP 41ECO HP 48ECO HP 55

Weil-McLain troubleshooting guides

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.