Weil-McLain Boiler: Wire external limit with automatic reset

Updated · by Aurora Star Tech Inc.

Wire external limit with automatic reset on a Weil-McLain boiler: Boiler shuts down when the limit opens and restarts automatically after the limit closes.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: ECO Tec Series 3 all models

How to fix wire external limit with automatic reset: step by step

  1. Remove the factory-installed jumper on J20 pins 3 and 4.
  2. Connect the isolated contacts of the external limits across J20 pins 3 and 4.
  3. When the limit opens, the boiler shuts down.
  4. The boiler restarts automatically 150 seconds after the limit closes.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: ECO Tec series 3 condensing gas boiler boiler manual, p. 71. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.