Weil-McLain Boiler: Inspect ignition electrode
Inspect ignition electrode on a Weil-McLain boiler: Clean or replace the ignition electrode and check the gap.
Applies to: ECO Tec Series 3 gas boilers
Common causes of inspect ignition electrode
- White oxide buildup on electrode
- Worn or damaged electrode insulation
How to fix inspect ignition electrode: step by step
- Remove the ignition electrode from the cover plate (Item 13, p. 153).
- Disconnect the ground wire and ignition cable.
- Discard the ignition electrode gasket.
- Remove white oxides with steel wool. If it cannot be cleaned, replace it.
- Make sure the electrode rods are parallel and the spark gap is 4.5mm.
- Fit a new gasket and reinstall the electrode.
- Use a torque wrench on the two retainer screws. Do not exceed 20 inch-pounds.
- Check the seal of the electrode, igniter gasket and cover plate to prevent gas leaks.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: ECO Tec series 3 boiler manual, p. 141. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.