Weil-McLain Boiler: Zoning with zone valves: two space heating zones
Zoning with zone valves: two space heating zones on a Weil-McLain boiler: Two space heating zones with no Indirect DHW, using zone valves and a system circulator. Shown for Heating Only models. The system must have a by-pass pressure regulating valve, because flow can occur with the zone valves closed.
Applies to: ECO Tec Series 3 Heating Only models
How to fix zoning with zone valves: two space heating zones: step by step
- Wire the zone thermostats to INPUT 2, 3 and 4. INPUT 1 is reserved for the system circulator setup.
- Wire Zone 1 and Zone 2 zone valves to Outputs 2 and 3, and the system circulator to Output 1 (2.2 A max).
- On Combi models, assign INPUT 2 (not INPUT 1) to AUX PUMP/OUTPUT, and the wiring for J17-4/5 applies.
- Assign INPUT 1 (INPUT 2 on Combi) to AUX PUMP/OUTPUT, then select INPUTS PRIORITY SETTING when prompted for when to activate the output.
- Confirm that PRIORITY 2 RUN AUX PUMP/OUT is set to YES so the system pump runs when either zone calls for heat.
- Set the space heating system type in PRIORITY 2 to match the heating system.
- Do not use a wired connection at INPUT 1 (J17-1/2), because it is used for the system circulator control.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: ECO Tec Series 3 boiler manual, p. 76. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.