Weil-McLain Boiler: Clean the DHW external filter and combi manifold filters
Clean the DHW external filter and combi manifold filters on a Weil-McLain boiler: Clean the domestic inlet water filter installed in the piping near the boiler, following the manufacturer's recommended cleaning procedure. On combi models, also clean the combi manifold DHW flow switch filter and the bypass filter. The DHW brazed plate should be cleaned annually, and more often if water quality requires it.
Applies to: Combi models for manifold filters; all models for the external inlet filter
How to fix clean the dhw external filter and combi manifold filters: step by step
- Clean the domestic inlet filter in the piping near the boiler using the filter maker's procedure.
- On combi models, clean the DHW flow switch filter and bypass filter per page 157.
- Clean the DHW brazed plate annually per page 154, or more often for poor water quality.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: ECO Tec series 3 boiler manual, p. 144. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.