Check control module fuses on a Weil-McLain boiler: Check both fuses before replacing the control module or major components such as the blower.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Ultra 80, 105, 155, 230, 299, 399

Common causes of check control module fuses

  • Blown low voltage fuse
  • Blown line voltage fuse

How to fix check control module fuses: step by step

  1. Turn off power to the boiler at the external line switch.
  2. Remove the jacket door and top panel. Swing the control panel forward to reach the U-Control module.
  3. Remove and inspect both fuses.
  4. Replace the low voltage fuse with a 3 A fast-blow (Littelfuse 257003) if needed.
  5. Replace the line voltage fuse with a 12 A slow-blow (Littelfuse 326012P) if needed.
  6. Never jumper a fuse or fit a different rating.
  7. Refit the top panel and jacket door, restore power, and verify operation.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: Ultra Series 4 gas-fired water boiler manual, p. 116. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.