Weil-McLain Boiler: Pilot lights but main flame does not light
Pilot lights but main flame does not light on a Weil-McLain boiler: Pilot is established but the main burners do not light.
Applies to: EG water boilers
Common causes of pilot lights but main flame does not light
- Main gas valve not energized
- Manual gas valve closed
- Manifold pressure incorrect during main ignition
How to fix pilot lights but main flame does not light: step by step
- Verify both main gas valves are being energized with 24 Vac.
- Verify all manual gas valves are in the open position.
- Verify manifold pressure during main flame ignition.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: EG / PEG Series 7 Boiler Manual, p. 75. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.