Weil-McLain Boiler: Priority timing (MAX ON and MIN ON)
Priority timing (MAX ON and MIN ON) on a Weil-McLain boiler: Priorities decide which system runs first. MAX ON TIME is how long a priority can run before a lower priority's call is served. MIN ON TIME is how long a priority must run before a higher priority or the next lower priority can take over. DHW on priority 1 is a typical example.
Applies to: ECO Tec Series 3 multi-system heating
How to fix priority timing (max on and min on): step by step
- Set MAX ON TIME for each priority so no system is held off too long.
- Set MIN ON TIME so the boiler does not switch priorities too quickly.
- Each priority keeps its own parameters, and the system type sets the defaults. Choose CUSTOM to create a new system type.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
More commissioning tips for boiler
Source: ECO Tec Series 3 Condensing Gas Boiler Boiler Manual, p. 85. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.