Weil-McLain Boiler: Route and seal wiring in the cabinet
Route and seal wiring in the cabinet on a Weil-McLain boiler: Line voltage and low voltage use separate knockouts. All entrances must be sealed.
Applies to: ECO Tec Series 3 all models
How to fix route and seal wiring in the cabinet: step by step
- Route line voltage through the bottom front left knockouts into the high voltage junction box. Strip wire no more than 1/4 in.
- Route low voltage through the bottom right or top right knockouts and connect directly to the matching terminal block.
- Use a strain relief at every knockout.
- Seal all electrical entrances with a sealed strain relief or duct seal putty or silicone to stop the boiler drawing air from the boiler room.
- Bundle wires with the supplied wire ties and secure the tie mount to the control bracket bottom right mounting hole.
- Install an On/Off service switch in a junction box near the boiler if required.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: ECO Tec series 3 condensing gas boiler boiler manual, p. 66-67. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.