Weil-McLain Boiler: Boiler will not light / repeated ignition failure

Updated · by Aurora Star Tech Inc.

Boiler will not light / repeated ignition failure on a Weil-McLain boiler: The control retries ignition after a failed flame check. After five failures it locks out for 60 minutes. Display banner turns red on an error or limit event.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Evergreen Series 2 control

Common causes of boiler will not light / repeated ignition failure

  • No flame signal at the electrode after ignition
  • Gas supply or gas valve problem
  • Error or limit event

How to fix boiler will not light / repeated ignition failure: step by step

  1. Watch the display banner. Red means an error or limit event.
  2. Let the 60 minute lockout run, or record the time of the failures.
  3. Check the gas supply and the gas valve.
  4. Check the electrode and flame signal.
  5. Check the flue and combustion air paths are clear.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: Weil-McLain Evergreen Series 2 advanced manual, p. 8. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.