Weil-McLain Boiler: Check combi DHW function, 3-way valve and brazed plate

Updated · by Aurora Star Tech Inc.

Check combi DHW function, 3-way valve and brazed plate on a Weil-McLain boiler: Verify the combi boiler switches between space heat and domestic hot water.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Combi models only

Common causes of check combi dhw function, 3-way valve and brazed plate

  • 3-way valve not switching
  • Leak at valve or brazed plate fittings
  • Clogged DHW filter

How to fix check combi dhw function, 3-way valve and brazed plate: step by step

  1. Give a heat call, then open a faucet to start a DHW call.
  2. Confirm the boiler and valve switch from space heating to DHW and hot water is delivered.
  3. If needed, run the 3-way valve test on p. 143.
  4. Check for water leaks at the 3-way valve, brazed plate and brazed plate manifold fittings.
  5. Clean the DHW brazed plate annually (p. 154).
  6. Clean the domestic inlet external filter and the combi manifold DHW flow switch and bypass filters (p. 157).
  7. Check DHW temperatures at all fixtures per the mixing valve procedure (p. 137). Check the recirculation pump, aquastat, timer or occupancy sensor if used.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: ECO Tec series 3 boiler manual, p. 144. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.