Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Weil-McLain Boiler: Install Weil-McLain sidewall vent/air plate

Updated · by Aurora Star Tech Inc.

Install Weil-McLain sidewall vent/air plate on a Weil-McLain boiler: Vent and air cap plates use a template and are fastened with screws and anchors. Plates are marked for the exhaust and intake openings.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: W-M vent/air plate and cap, sidewall direct vent

How to fix install weil-mclain sidewall vent/air plate: step by step

  1. Set the paper template on the outside wall and level it. Mark the four mounting holes and the vent and air openings.
  2. Make sure the template is level so the vent and air pipes sit side by side.
  3. Cut the holes using a small centering bit first, then drill the large openings from both sides. A rectangular cutout may be used instead of two holes.
  4. Drill the screw holes and fasten the outside plate.
  5. Cut the vent pipe so it fully enters the termination socket, and cut the air pipe so it butts against the interior stops.
  6. Slide the pipes through the openings and fit the inside plate, sloping pipes down toward the boiler at 1/4 in per foot.
  7. Remove the pipes, drill the four mounting holes, and fasten the inside plate.
  8. Test-fit the termination on the vent pipe.
  9. Apply silicone RTV sealant inside the vent termination and slide it onto the vent pipe. Rotate slightly to spread the sealant.
  10. Secure the termination with four #10 x 1/2 in sheet metal screws and lock washers.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: ECO Tec Series 3 boiler manual, p. 37-38. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.