Weil-McLain Boiler: Clean condensate trap

Updated · by Aurora Star Tech Inc.

Clean condensate trap on a Weil-McLain boiler: Clean the condensate trap at each annual startup.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: ECO Tec Series 3 gas boilers

Common causes of clean condensate trap

  • Sediment in trap
  • Blocked condensate drain

How to fix clean condensate trap: step by step

  1. Remove the pedestal front access panel if floor standing.
  2. Loosen the hose clamp and pull the trap down to disengage the drain tube.
  3. Remove the clean out cap and take out the trap internal parts.
  4. Clean all trap components.
  5. Reassemble and reinstall all lower gaskets.
  6. Make sure the trap ball moves freely.
  7. Fill the trap with fresh water through the top until water flows out the drain line.
  8. Reattach the trap to the condensate outlet, push up until fully engaged, and retighten the hose clamp.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: ECO Tec series 3 boiler manual, p. 140. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.