Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Weil-McLain Error Code SUPPLY 58F > RETURN: Supply temperature far above return (Boiler)

Updated · by Aurora Star Tech Inc.

Weil-McLain error code SUPPLY 58F > RETURN on a boiler means: Supply temperature far above return. It is also called Weil-McLain diagnostic code SUPPLY 58F > RETURN.

Medium severityBoilerUltra Series 4

Homeowner? What Weil-McLain code SUPPLY 58F > RETURN means for you

Check, then call Your boiler is reporting: Supply temperature far above return. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code SUPPLY 58F > RETURN mean?

Boiler outlet temperature is more than 58 °F above boiler inlet temperature while the burner is on. Resets automatically after a 30 second delay, or manually from the display.

Applies to: Ultra 80, 105, 155, 230, 299, 399

Common causes of Weil-McLain code SUPPLY 58F > RETURN

  • Water flow through the boiler too low
  • Piping not primary/secondary
  • Circulator undersized or wrong size for the boiler
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Weil-McLain Boiler codes

CodeMeaning
NO DISPLAY - NO 24VNo display, no 24V control power
NO DISPLAY - NO 120VNo display and no boiler components running, no 120V power
RETURN > SUPPLYReturn temperature above supply
Software IncompatibleMain control and display software mismatch
SPILL SWITCHSpill switch open (flue gas spilling at the draft hood)
STANDBYStandby display
SUPPLY 58° F > RETURNSupply exceeds return by 58°F
Supply 60F > ReturnSupply more than 60F above return (soft lockout)
SUPPLY WATER TEMPERATURE TOO HIGHSupply temperature above 200°F while burner runs
System Return > SupplySystem return hotter than system supply
Target Reduced - BoilerTarget reduced because boiler outlet is near max temperature
Target Reduced - FlowTarget reduced for low water flow across heat exchanger

All Weil-McLain Boiler error codes →

Weil-McLain code SUPPLY 58F > RETURN: homeowner questions

What does Weil-McLain code SUPPLY 58F > RETURN mean?

Supply temperature far above return. Boiler outlet temperature is more than 58 °F above boiler inlet temperature while the burner is on. Resets automatically after a 30 second delay, or manually from the display.

Is it safe to keep using my boiler with code SUPPLY 58F > RETURN?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Weil-McLain code SUPPLY 58F > RETURN myself?

You can try one reset (power off for 30 seconds, then on). If Weil-McLain code SUPPLY 58F > RETURN comes back, the cause is still there and a licensed technician should check it.

Who can fix Weil-McLain code SUPPLY 58F > RETURN near me?

Aurora Star Tech Inc. repairs Weil-McLain boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Ultra Series 4 gas-fired water boiler manual, p. 119. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977