Weil-McLain Boiler: Express Setup Example A – application summary
Express Setup Example A - application summary on a Weil-McLain boiler: Example A is a multi-zone space heating system with circulators that have no circulator relays, plus direct-piped indirect DHW. The default control settings only apply if the indirect water heater is direct piped to the boiler. Relief valve must be piped to the boiler In connection.
Applies to: Single boiler, multi-zone space heating with indirect DHW, Express Setup Example A
How to fix express setup example a - application summary: step by step
- Confirm the indirect water heater is direct piped to the boiler before relying on default settings.
- Pipe the boiler relief valve to the Boiler In connection, and run relief piping to drain.
- Wire the 120VAC supply to the boiler and install the outdoor sensor.
- Confirm supply and return temperature sensors and the low water cut-off are installed.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
More commissioning tips for boiler
Source: ECO Tec Series 3 boiler manual, p. 89. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.