Space multiple boiler terminations on a Weil-McLain boiler: When more than one boiler vents through the same wall or roof, terminations must line up and keep minimum spacing.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Multiple boiler vent and air terminations

How to fix space multiple boiler terminations: step by step

  1. Set all vent pipes to terminate at the same height.
  2. Set all air pipes to terminate at the same height.
  3. Keep at least 12 in between the air intake edge and the vent pipe of an adjacent boiler.
  4. Keep maximum separation between vent and air pipes for each boiler as shown in the sidewall layout.
  5. For Canadian installs, follow CSA B149.1 or B149.2 and use a ULC S636 compliant vent kit.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: ECO Tec Series 3 boiler manual, p. 33-35, 39-40. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.