Weil-McLain Boiler: Frequent release of water through relief valve

Updated · by Aurora Star Tech Inc.

Frequent release of water through relief valve on a Weil-McLain boiler: Relief valve keeps discharging water, pointing to expansion tank or limit control problems.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: All listed CGa, CGi, EG, PEG and LGB boilers

Common causes of frequent release of water through relief valve

  • Expansion tank sized too small
  • Expansion tank flooded
  • Inoperative limit control (steam boiler)

How to fix frequent release of water through relief valve: step by step

  1. Have a qualified service technician check expansion tank operation and size
  2. Have a qualified service technician check the expansion tank for flooding
  3. On a steam boiler, have a qualified service technician replace the limit control
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: Weil-McLain CGa, CGi, EG, PEG & LGB user manual, p. 9. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.