Weil-McLain Boiler: Combustion air contamination and air intake location
Combustion air contamination and air intake location on a Weil-McLain boiler: Contaminated combustion air will damage the boiler. Keep the air intake away from sources of chemicals and dust.
Applies to: All Ultra boiler installations, direct vent and direct exhaust
Common causes of combustion air contamination and air intake location
- Chloro/fluorocarbon sprays, bleaches, chlorine chemicals, refrigerant leaks, cements, adhesives, dust
- Air intake near pools, laundry exhaust, dry cleaning, auto body, beauty shops, plastics or construction areas
How to fix combustion air contamination and air intake location: step by step
- Do not put the air intake or air supply opening near a swimming pool or laundry exhaust.
- Avoid areas with metal fabrication, refrigeration repair, photo processing, furniture refinishing, remodeling or construction dust.
- Do not use products from the avoid list (chlorinated cleaners, paint removers, muriatic acid, calcium or sodium chloride, antistatic dryer softeners) where they could reach the combustion air.
- Confirm the air supply meets local code and the Air for Combustion and Ventilation requirements (ANSI Z223.1/NFPA 54 or CSA B149.1).
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: Weil-McLain Ultra Series 4 boiler manual, p. 16-17. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.