Weil-McLain Boiler: Set outputs to CAD interlock mode

Updated · by Aurora Star Tech Inc.

Set outputs to CAD interlock mode on a Weil-McLain boiler: When Input 3 is used with a CAD, set the output mode so the damper opens on every call to fire.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Evergreen 110/155/220/299/300/399

How to fix set outputs to cad interlock mode: step by step

  1. Assign Input 3 as AUX PUMP/OUTPUT.
  2. Set the operating mode to local or System Damper.
  3. Confirm Output 3 supplies 120VAC to the damper motor.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

More other tips for boiler

Source: Weil-McLain Series 2 Condensing Gas Boiler Advanced Manual, p. 52. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.