Weil-McLain Boiler: Radiators or baseboard units do not heat or are noisy
Radiators or baseboard units do not heat or are noisy on a Weil-McLain boiler: Heat distribution problem usually caused by air in the system or low system pressure.
Applies to: All listed CGa, CGi, EG, PEG and LGB boilers
Common causes of radiators or baseboard units do not heat or are noisy
- Air in system
- Low system pressure
- High limit set too low (steam boiler)
How to fix radiators or baseboard units do not heat or are noisy: step by step
- Bleed air from the system through the air vents in the radiators or baseboard units
- Fill the system to the correct pressure
- Check for leaks in boiler or piping and have a qualified service technician repair them at once
- On a steam boiler, adjust the high limit to a higher setting
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: Weil-McLain CGa, CGi, EG, PEG & LGB user manual, p. 9. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.