Weil-McLain Boiler: Converting the boiler from natural gas to propane

Updated · by Aurora Star Tech Inc.

Converting the boiler from natural gas to propane on a Weil-McLain boiler: The boiler ships set for natural gas and needs a propane orifice for propane. Use only the orifice in the conversion kit, which is 0.660 inch and marked for this boiler size. The conversion must be done with the electrical supply off and the external manual gas valve closed. After conversion, start up and test the boiler to check combustion. High altitude installs use the control's High Altitude option (Figure 67, page 75).

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: SVF 1500/2000/2500/3000 converting to propane

How to fix converting the boiler from natural gas to propane: step by step

  1. Turn off power and the external manual gas shut-off valve; let the boiler cool if it was running.
  2. Verify the orifice disk stamping is correct for the model size and reads 0.660 inch.
  3. Remove the left front side panel.
  4. Remove the gas manifold: four M5 bolts at the mixing system/blower (7mm Allen) and four M8 bolts at the gas valve (13mm socket or wrench).
  5. Inspect the gas valve and mixing system/blower O-rings and replace if damaged.
  6. Install the propane orifice in the groove.
  7. Reinstall the manifold, making sure both O-rings are in place, and tighten the M5 and M8 bolts.
  8. Confirm flanges are flat to mounting surfaces with no gaps, then reconnect power.
  9. Set the control to LP GAS in the Wizard or boiler settings menu.
  10. Start up, test and adjust the boiler, including the flame and combustion checks on page 88.
  11. Apply the conversion label next to the rating label.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: SVF 1500-3000 Series 1 boiler manual, p. 12. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977