Weil-McLain Boiler: Zoning with circulators: three zones plus Indirect DHW
Zoning with circulators: three zones plus Indirect DHW on a Weil-McLain boiler: Three space heating zones plus an Indirect DHW tank piped directly to the boiler. Shown for Heating Only models.
Applies to: ECO Tec Series 3 Heating Only models
How to fix zoning with circulators: three zones plus indirect dhw: step by step
- Wire the DHW aquastat to INPUT 1 and assign INPUT 1 to PRIORITY 1.
- Wire the zone thermostats to INPUT 3 and INPUT 4 and the other space heating input as shown.
- Wire circulators to Outputs 2, 3 and 4 (2.2 A max each).
- Set the space heating priority (PRIORITY 2) to the heating system type during the WIZARD or in System Settings.
- Use the factory default settings for DHW and the heating system type, or change them if needed.
- On Combi models, Input/Output pairs 1 and 4 are used for the 3-way valve and cannot be used for other purposes.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: ECO Tec Series 3 boiler manual, p. 75. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.